Reactor | Operating parameters/Biomass | CO % | H2 % | CH4 % | CO2 % |
Auger Gasifier 1 | 700˚C - 850˚C Soybean residues | 15.0 - 23.8 | 1.1 - 3.3 | 5.1 - 7.7 | 15.9 - 19.7 |
Auger Gasifier 2 | 750˚C Cotton gin | 12.6 | 8.1 | 4.1 | 14.3 |
Updraft Gasifier | A/F 1.1 - 1.55 Wood | 28 - 30 | 6 - 8 | 1 - 2 | 5 - 7 |
Downdraft Gasifier | ER = 0.16 - 0.35 Wood | 20 - 25 | 10 - 15 | <5 | - |
Circulating fluidized bed 1 | 728˚C Wood | 19.9 | 5.1 | 4.1 | 14.5 |
Circulating fluidized bed 2 | 750˚C Rice husk | 27.5 | 47.8 | 6.6 | 18.1 |
Bubbling fluidized bed | 800˚C Wood | 14.0 | 7.0 | 3.0 | 13.5 |